emid_cuts package modifications
- p21-br-25 : November 18, 2009:
Update to new emid definitions: Point0, Point1 and Point2 and Point_skim.
- p21-br-23 : October 2, 2009:
Simplified cuts (logic stays the same), remove the pT cut from here and move it to the ElectronSelector.
- p18-br-11, p21-br-22 : December 6, 2008:
we have found and fixed bug for Medium & Tight selections in EC in emid_cuts:
Lhood8 cuts >0.2 and >0.8 that assumed to be applied just in CC
were also cutting events in EC.
- p21-br-20 : November 15, 2008: take into account likelihood cut for track match flag.
- p18-br-10, p21-br-19 : November 18, 2008:fixed bug for top_loose(tight) v4
- p18-br-09, p21-br-18 : November 17, 2008:modified track match informational methods
- p18-br-08, p21-br-17 : November 5, 2008: updated several new definitions
- p18-br-07 : Octobre 20, 2008: updated code for emid_cuts
- p18-br-06, p21-br-92 : Octobre 10, 2008:
Top_loose and Top_tight definitions are modified to overcome the problem with the track matching variable in reCAFed p17 data.
(see report at Conveners meeting)
In CC only, the track matching cut, TrkMatchChi2EOP > 0.0, is replaced by the following:
- TrkMatchChi2_CC > 0.0
- EOP_CC < 3.0
but in EC it is still the same:
- TrkMatchChi2EOP_EC > 0.0
The new definitions are available inside
emid_cuts/support/emid_cuts.txt
as version 4 and efficiency correction (from emid_eff)
as version 6.
More details are on this WIKI page.
- p18-br-05, p21-br-15 September 17, 2008:
Defenition modification to garantee that tighter definition is
a subsample of the loose one.
- p18-br-04 September 10, 2008: New EM ID defenitions for p18.
- p21-br-14 June 7, 2008:
Here is list of the packages needed to work with
electron/photon ID definitions for ICHEP 2008:
- addpkg emid_cuts p21-br-14
- addpkg caf_util p21-br-72
- addpkg emid_eff v7-preliminary-23
- addpkg caf_eff_utils p21-br-07
- addpkg tmb_tree p21-br-39
They now contain all necessary eff-cy/SF correction
(including track matching and track pT smearing) and tools for ICR electrons.
As compared with a previous version we have also tightened
a bit cuts for the p20-style electron ID (for Loose, MLoose1 and MLoose2)
in EC region and added one more operation point for the trackless
electron ID in EC (Medium).
This config file
caf_util/configs/test_ele.config
contains an example on how to run electron ID.
For photon ID we have added calculation of ANN-6 for CC photons,
which output is available thru method NNout6_gamCC() of TMBEMcluster.
See also Wiki page.
- p21-br-12 May 9, 2008: bug fix in emid_cuts.hpp
- p21-br-11 May 5, 2008: modified emid_cuts.cpp * hpp: corrected one criteria in the new EMID definition and improved statistics
- p21-br-10 May 2, 2008: modified emid_cuts.cpp (LHood bug for Med/Tight for v.11)
- p21-br-09 Apr 30, 2008: re-defined MLoose2 for EC
- p21-br-08 Apr 29, 2008: corrected emid_cuts.txt
- p21-br-07 Apr 29, 2008: new emid cuts
- p21-br-06 Dec 21, 2007: Modified method emid_cuts::Stat(). Modified list of selection criteria
- p18-br-03 May 4, 2007: fixed reading fiducial cut files
- p18-br-02 Apr 3, 2007: fixed COMPONENT file
- p18-br-01 Apr 2, 2007: add fiducial cuts
Fabrice Couderc
Last modified: Tue Nov 18 16:27:07 CST 2009