Level 3 histograms are available by running the trigger_examine process. This process runs as an examine from the data distributor. It produces a rootuple from the L3fAnalyze process. A second process then generates a series of histograms from the rootuple output.
The following pages of plots are available from the trigger gmbrowser:
Please check that histograms match the red reference histograms.
| GM Page | Requirements | Plots | Things to check |
| L3 elec | All L3 electrons, ET > 5 | Number of electron candidates | |
| Calorimeter cluster EM fraction | Should peak around 1. | ||
| Calorimeter cluster Phi | Should be flat. | ||
| Calorimeter cluster Eta | |||
| EM_HI | EM_HI electron trigger | Number of electron candidates | |
| Calorimeter cluster EM fraction | Should peak around 1. | ||
| Calorimeter cluster Phi | Should be flat. | ||
| Calorimeter cluster Eta | |||
| EM_HI_SH | EM HI electron trigger w/ shower shape cut | Number of electron candidates | |
| Calorimeter cluster EM fraction | Should peak around 1. | ||
| Calorimeter cluster Phi | Should be flat. | ||
| Calorimeter cluster Eta | |||
| EM_HI_TR | EM HI electron trigger w/ track requirement | Number of electron candidates | |
| Calorimeter cluster EM fraction | Should peak around 1. | ||
| Calorimeter cluster Phi | Should be flat. | ||
| Calorimeter cluster Eta | |||
| EM_HI_EMFR8 | EM HI electron trigger w/ loose EMFR cut | Number of electron candidates | |
| Calorimeter cluster EM fraction | Should peak around 1. | ||
| Calorimeter cluster Phi | Should be flat. | ||
| Calorimeter cluster Eta | |||
| L3 Muons | Currently not used in trigger. | ||
| L3 jets 1 | Jet candidates in the SCJET9 tool. | Number of jets above Et threshold. | |
| Jet eta (wrt primary vertex) | |||
| Jet phi | Should be flat. | ||
| Jet Et (wrt primary vertex) | |||
| L3 jets 2 | Jet candidates in the SCJET9 tool. | Et fraction in EM layers. | |
| Phi versus eta. | Empty bins. | ||
| kineX | |||
| kineY | |||
| L3 taus | Tau candidates in the TAU_LOOSE_TRACK trigger. | Number of tau candidates. | |
| Cluster pseudorapidity wrt vertex used by calorimeter tool. | |||
| Cluster phi | Should be flat. | ||
| Cluster transverse energy | |||
| L3 tracks | Global Tracker debug information. | Number of L3 tracks. | |
| Number of hits/track. | |||
| Phi of each track. | Should be flat. | ||
| L3 MET | L3 Missing ET for CalMEt_PvtxZ. | Missing ET. | |
| MEt component in the x-direction. | |||
| MEt component in the y-direction. | |||
| Scalar ET |