Muons(A-Stub) These are the same plots as MUONS(ALL) except for A-stubs. A-stubs have no B or C-layer hits. N ----- The number of Astub muons of all kinds. PT ----- The pT (GeV/c) of A-stub muons. This comes from the tracker if the muon is matched. I don't know how the pT would be known, otherwise. ETA ----- Eta of A-stub muons. The peaks near |eta|=1 are due to background scattered into the central region from the exit of the calorimeter. PHI ----- Phi of A-stub muons. The deficit at phi~5 is because of there is 16% of phi in central region which supports the calorimeter. The are no A-layer detectors there. CHISQ ----- The chi-sq of the track fit. CHISQLOC -------- The chi-sq of the fit for the muon local track (muon hits only). E33 ----- The energy deposited in a 3x3 cone in the calorimeter (corresponding to delta eta x delta phi of 0.3 x 0.3) centered around the expected position the muon enters it. Muons deposit between 1 and 2.5+ GeV in the calorimeter depending on the angle it goes through. HALO ----- The energy in a ring of inner radius xxx and ounter radius yyy. This helps determine muon isolation. W HITS A -------- The number of PDT and/or MDT hits in the A-layer. Most of the A-layer has 4 decks. The central bottom has 3 decks. Parts of octant 5 & 6 have no A-layer coverage at all. W HITS BC --------- There are no BC hits on AStubs. SCINT HITS A ------------ The number of A-layer scintillator hits. SCINT HITS BC ------------- There are no BC hits on AStubs.