============================== b01.txt ============================== p20.11.01 build 1 - 23 Oct 07 == Level 2: cwiok/hirosky l2gbltau p20-br-03 <- p20-br-01 New build to move code from l2p20.04 -> l2p20.11 Adds track matching to tau tool. For v16 trigger lists only; not compatable with v15 lists. On a successful track match, track phi is used as the phi of the tau. ============================== b02.txt ============================== l2p20.11.01 build 2 - 23 Oct 07 == Level2: cwiok l2cal2bmetworker v00-02-01 <- new New in p20.11 ============================== b03.txt ============================== l2p20.11.01 build 3 - 8 Nov 07 == Level2: jakraus l2admin l2-02-01-07 <- l2-02-01-06 Updated CalProcessing to send output of MET worker to L2GBL ============================== b04.txt ============================== l2p20.11.01 build 4 - 14 Dec 07 == Level 2: jakraus l2admin l2-02-02-00 <- l2-02-01-07 Changed the output buffer offset used to grab the L1 decision from 40 bytes to 56 bytes. 40 bytes = L2 decision, 56 = L1 decision l2gblmuon p20-br-03 <- p20-br-02 Fixed bug in MuonFilter.cpp. The code was checking the Toriod pt and muon pt (which is either the Toroid pt or the associated track pt, depending on how the muon tool is configured), and passed the event if either passed the pt cut. Now the muon filter only checks the muon pt.