The motor is connected to the driver by a 3 meters braided shield 3 AWG 16 wire cable. A ferrite absorber at the driver cable end is used to help keep noise at low level.
The driver is feeded by 110V mains from a TEV separated circuit thrugh a 6A line filter (Corcon 6EQ1) and it is protected by a 3A AG3 slow blow fuse.
The driver and filter are installed in a closed convection ventilated 19" aluminum crate and the fuse is accessible at the crate back.
Driver power cable from the filter is a custom made braided shield 3 AWG16 wire cable and have a ferrite absorber at the driver end.
A braided shield control cable (TTL level),3 meters length, runs from the driver to the indexer interface and it has a ferrite absorber at the driver end.
All cables braids are inside connected to the crate back plane to keep noise at low level. The back plane is connected to the mains ground.