September 19,2002
V.Sirotenko
FPD
RM Configuration
====================
This is
a brief summary of current RM configuration after MUX installation
There
are 5 RM in the tunnel, one for each castle.
EPICS
names from FPD RM are the following:
P1:
FPD_RM_02-11
P2:
FPD_RM_02-13
A1:
FPD_RM_02-01
A2:
FPD_RM_02-03
D :
FPD_RM_02-05
Digital ports configuration:
P2 (
bin05, 1 port ) à output
P7 (
bin06–bin13, 8 mux ports ) ß
input
P3 (
bin00, 1 port )
ß
input
P8 (
bin01–bin04, 4 mux ports ) à output
where
bin** - fields of RM EPICS record
Piano
switches on the RM front panel must be set as
-_ _--_
Digital
ports details (lower bit is 0) :
P2
(bin05) : Software Control Command
bit 4: smoke reset, =1 all the time, =0
when reset
bit 5: control of driver power box, =1
on, =1 off
bit 6: control of amplifier board power
box, =1 on, =1 off
bit 7: software emergency line (not
implemented)
bit 8: not used
P8
(bin01–bin04) : Pot Motion Command, 16 bit word
bin01 - control of UP pot
bin02 - control of DOWN pot
bin03 - control of IN pot
bin04 - control of OUT pot
P3
(bin00) : Software Control Status
bit 0: smoke signal, =1 no smoke, =0
smoke
bit 1: driver power box status, =1 on, =1
off
bit 2: amplifier board power box status,
=1 on, =1 off
bit 3: control line status, =1 enabled,
=0 disabled
bit 4: emergency line status, =1
emergency, =0 no emergency
bit 5: readout of what is written in bit
5 of P2
bit 6: readout of what is written in bit 6 of P2
bit 7: readout of what is written in bit
7 of P2
bit 8: readout of what is written in bit
8 of P2
bit 9 – bit 11: low bits of RMI
geographical address (not implemented)
P7
(bin06–bin13) : Pot Motion Status
bin06 – readout of what is written in P8,
bin01
bin07 - readout of what is written in P8,
bin02
bin08 - readout of what is written in P8,
bin03
bin09 - readout of what is written in P8,
bin04
bin10 – status of UP pot, 8 bits
bit
0: cable status bit, =0 ok, =1 failure
bit
1: home bit, =0 not home, =1 home
bit
2: in bit, =1 in, =0 out
bit
3: motion bit, =0 stop, =1 motion
bit
4: mechanical status, =0 ok, =1 failure
bit
5: driver status, =1 ok, =1 failure
bit
6: direction, =1 in, =0 out
bin11 – status of DOWN pot, 8 bits
bin12 – status of IN pot, 8 bits
bin13 – status of OUT pot, 8 bits
Analog ports configuration:
AD32
: raw LVDT from UP pot
AD33
: raw LVDT from DOWN pot
AD34 : raw LVDT from IN pot
AD35
: raw LVDT from OUT pot
where
AD** - fields in FPD_RM_02-xx RM record