Muon High Voltage User’s Guide
Huishun Mao, Dehong Zhang and Tom Diehl
1. SETUPS
Request 3 setups for d0mino.fnal.gov .
> setup n32
> setup D0RunII
> setup d0python
Only need one setup for d0ola.fnal.gov
> setup d0python
2. RUNNING High Voltage System
Both for d0mino.fnal.gov and d0ola.fnal.gov
> cd ~mao/hvmus
> hv muhv_??.dat
??
can be a, b, c, pad and wire, corresponding to A, B orC layer Scintillator counter or WAMUS pad and wire High Voltage.
For example,
> hv muhv_c.dat (will run C layer Scin. H.V. and get a Figure 1 as following)
> hv muhv_pad.dat (will run WAMUS pad H.V. and get a Figure, similar Figure 1)
How to Run the displayed Figure
Here will be 0%, 10%, 20%, …… 80%, 90%, 100% for your choice.
For normal running, 100% will be selected
How to turn off
Figure 1

How to Run single or only several Channels
If only one or several channnels request High Voltage, such as C layer No.28,
with left mouse key. The color in the cell will change to yellow .
Click the yellow cell with right mouse key, the old set value will disappear
Write New H.V.Value, which you want, into the cell
Click Return (or Enter) Key The H.V. Set will be finished.
Choice Turn On
Click Cell once more
Choice RAMP H.V. will reach your set value in channel 28
Choice Turn Off Run Finished
3. MAP of H.V. Channels Corresponding to Detector
(Careful, must teurn and ramp PAD H.V. first, before running wire H.V.)