Fermilab


MDT


[Technical Design Report]
[MDT Cabling]


Mini-Drift Tubes (MDT)

Detectors

10 decks / octant
4 A-layer decks / octant
3 B-layer decks / octant
3 C-layer decks / octant
preliminary channel count (within 2%):
A-layer
960 cells / octant / side
B-layer
octants 0,1,2,3,4,7
1056 cells / octant / side
octants 5,6
768 cells / octant / side
C-layer
octants 0,1,2,3,4,7
1320 cells / octant / side
octants 5,6
768 cells / octant / side

Mini-Drift Digitizing Cards (MDC's) (front end cards)

192 channels / MDC capacity
134 MDC's / side * 2 sides = 268 MDC's
A-layer
5 MDC's / octant / side
B-layer
octants 0,1,2,3,4,7
6 MDC's / octant / side
octants 5,6
4 MDC's / octant / side
C-layer
octants 0,1,2,3,4,7
7 MDC's / octant / side
octants 5,6
4 MDC's / octant / side
outputs:
2 cables / MDC to MCEN (96 bits / cable)
location:
MDC crates (trusses)

Mini-Drift Readout Controller (MDRC) cards

1 Digital Signal Processor (DSP) / MDRC
1 readout controller / MDRC
inputs:
3 coax cables / MDRC from MRC for timing signals
1 twisted & flat cable for control signals to and from MRC
outputs:
1 coax cable / MDRC for serial link to L2 (L2 data from DSP via HOTLink)
1 coax cable / MDRC for serial link to MRC (L3 data from DSP via HOTLink)
location:
MDC crates (trusses)

MDC Crates

24 crates
8-14 MDC's / crate
2 octants / layer / crate
(grouped by octants 7&0, 1&2, 3&4, 5&6)
1 Mini-Drift Readout Controller (MDRC) / crate
1 680xx processor card / crate
location:
crates for octants 7&0, 3&4: vertical trusses
crates for octants 1&2: top trusses
crates for octants 5&6: bottom forward regions; between MDT planes?


Last modified: sep 21, 2004