D0 Muon Electronics Homepage
Last updated on December 08, 2003
Muon Electronics for Run II:
What's new on this page?
Muon Electronics in general
ECB related documents
Muon Electronics in IEEE Publications
Muon Electronics Tecnical Design Report
What's new on this page?
We have converted
most of the files into Adobe PDF file format to increase downloading speed.
You can download
Adobe Acrobat Reader 4.0 free from here.
Go to the top of the page
Muon Electronics in general
Upgraded muon system for Run II consists of three basic subsytems
which include existing WAMUS proportional drift tube (PDT) chambers,
scintillation counters (SC) and mini-drift tubes (MDT). The old analog
electronics for WAMUS chambers has been replaced due to the new
requirements based on the beam structure.
New scintillation and mini-drift tube detectors require new
electronics. All electronics except the readout electronics are
located in the D0 collision hall. This includes approximately 9,500
channels of on-chamber PDT (WAMUS) electronics, 6,000 channels of
scintillation counter electronics and 50,000 channels of mini-drift tube
electronics. Design of the electronics for each muon
subsystem is based on a common strategy described as follows:
- continuous digitization of the input data
- adjustable digital delays to accomodate
Level 1 trigger latency
- Level 1 FIFOs for buffering Level 1 data in hardware
- use of DSPs for data preprocessing and managing Level 1 and
Level 2 data buffers
- high speed copper serial links to transfer trigger and data
information
- stand-alone calibration and test capabilities
During 1994-1995 a conceptual design of the
deadtimeless data
readout system was developed and finalized. The design and prototyping of the electronics is
finished and its production for all subsystems is complete. D0 Muon Electronics group provides
technical support for installation and commissioning efforts. The collaborating
institutions PNPI (Gatchina, Russia) and JINR (Dubna, Russia) are supporting
mini-drift tube front-end electronics and amplifier-discriminator board (ADB)
electronics respectively. Fermilab part of the
D0 Muon Electronics group is responsible for readout electronics,
which are common for all muon subsystems, PDT (WAMUS) front-end electronics and
scintillator front-end electronics. The latter two are based on the new
TMC-TEG3
CMOS chip developed by Y.Arai from KEK.
For additional information see D0 Notes 2370, 2705, 2780, 3062.
The configuration
of the muon electronics is almost finalized. You can find an overview of the
muon electronics configuration here.
A current version of the
D0 electronics layout is available here. The muon only
MCH3 electronics layout is also available.
Muon cable plant consists mainly of
the existing cables for Run I. Initial consideration of this topic is available
here.
All muon electronics comply with D0 DAQ specifications (SCL
spec and GS spec).
Internally, we have several additional features defined within frames of the
mentioned above specs. The INIT signal is processed by muon front-ends according to
the
muon GS spec.
In order to make our new electronics look better we proposed a
unified mechanical spec for
VME based modules developed for the muon system. These modules require special
9U VME crates to function properly. The crates are air cooled and designed to work at
normal ambient temperature (25 degrees C) at their location. For details see
D0 Muon Front-End Crate Installation Specification.
Unified data formats for all subsystems are developed by
Muon On-line Software group.
A current version of the
Muon Data Formats for L2 & L3specification is available.
Go to the top of the page
Commissioning Status
Muon Electronics is fully installed and running. We need to complete the commissioning by eliminating
the remaining few minor problems. We will place here weekly reports from Muon Commissioning meetings while
those problems persist. The Muon Electronics is divided into pieces by Geographic Sections (GS). Each GS consists
of Muon Readout Crate and associated Front-End crates.
The following crate IDs are used for muon sub-systems:
- PDT crates have IDs 34, 35, 36, 38, 39, 3a (hex)
- Scintilator Crates have IDs 32, 33 (FAMUS) and 37, 3b (WAMUS) (hex)
- MDT crates have IDs 30, 31 (hex)
Summary from Muon Commissioning meetings:
Go to the top of the page
Readout Electronics
Muon data readout is based on two unified interface modules:
Muon Fanout Card (MFC) and Muon Readout Card (MRC). The MRC interfaces muon readout crate to
the front-end electronics. The MFC interfaces muon readout crate to the D0 Trigger Framework (TFW).
The MRC and MFC are slave VME modules controlled by a commercial VME processor Motorola
MVME162 and
VME Buffer Driver (VBD) card. A general description of the MFC and MRC
can be obtained from IEEE publication "D0 Muon Readout
Electronics Design". There is also a Trigger Fanout Card (TFC) which is
dedicated mainly for local system tests and diagnostic when D0 DAQ and/or
TFW are not present or not available. For diagnostic purposes we have developed a HP analyzer
adapter board. This board can be plugged in the readout crate and provides standard set of TFW
related signals on 34 pin connectors matching HP 1660 series analyzer cables. All muon readout
electronics are located
in the Movable Counting House (MCH) on a 3rd floor of the D0 Assembly Building.
All the cards are realized as 9U x 280 mm VME modules and are housed in the
21 slot 9U VME crates. These crates have a custom 9U size backplane that utilizes user
defined J2 and J3 connections.
One of the important features of the MRC and MFC modules is a transmittion
of the timing signals to the front-end electronics. These signals are received
and distributed by the MFC and MRC modules. Wide bandwidth coaxial ribbon
cable is used to bring timing signals to the controller units in the front-ends.
Readout Electronics Updates:
Muon Readout Electronics Pictures (click to zoom in):
Go to the top of the page
Monitoring and Control
All muon sub-systems have 1553B bus interface as a primary tool to provide monitoring
and control capabilities. Communication with muon Remote Terminals (RT) is
supported by existing run I hardware and EPICS software. For details on
EPICS software see
on-line systems web page. All muon front-ends also have a custom RS-232 serial link
that uses two twisted pairs in 50 conductor cable connecting MRC to the front-ends. This
link is used to generate BREAK signal during readout crate power-up and subsequently
reset front-ends to the initial state. It also can be used as a substitute for the 1553
bus connection in local readout mode and stand alone configurations.
We have specified 1553 RT address assignment for three muon detector
subsystems:
Go to the top of the page
PDT Electronics
A general description of the PDT electronics can be obtained from IEEE
publication "D0 Upgrade Muon Electronics Design".
The PDT electronics consists of Front-End Board (FEB) and Control Board (CB).
Both boards are located on muon PDTs and have non-standard physical dimensions.
PDT Electronics Tests
PDT Electronics test results are available in Adobe PDF format:
PDT Electronics design updates
Recent PDT Electronics updates include:
PDT Electronics Pictures (click to zoom in):
Go to the top of the page
Scintillator Electronics
The Scintillator Electronics consists of Scintillator Front-End card (SFE)
and Scintillator Read-out Controller (SRC). There is also an auxillary
Scintillator LED Pulser (SLP) module
dedicated to drive LED test system (see D0 Note 3563) for phototube monitoring.
Scintillator electronics are housed in 9U VME crates and are located in
the collision hall. The crates are distributed around the D0 detector. All the
cards are based on 9U x 280 mm VME modules.
SC Electronics design updates
Recent SC Electronics updates include:
Scintillation Counter Electronics Pictures (click to zoom in):
Go to the top of the page
MDT Electronics
The MDT electronics include amplifier-discriminator boards (ADB) and VME-based
front-end electronics consisting of mini-drift tube digitizing card (MDC)
and mini-drift tube readout controller (MDRC).
The ADBs are located on mini-drift tubes. The MDC and MDRC are housed in
the similar to the scintillator electronics 9U VME crates. The MDT
crates are located on the north and south EFs and trusses.
Mini Drift Tube Electronics Pictures (click to zoom in):
Go to the top of the page
Muon Electronics maintenance
We have transferred maintenance and repair of some of the Muon Electronics modules
to Fermilab PREP. PREP currently provides necessary techincal and logistic support
for the following projects:
- Muon Readout Card (Full Repair Support)
- PDT Front-End Board (Full Repair Support)
- Muon Front-End VME crates (Full Repair Support except VICOR power supplies)
For the listed above projects contact CD at extension x2695
Go to the top of the page
Up-to-date ECB-related documents:
- SCL Specification
- GS Specification
- SCL Mezannine Card Specification
are available from
Electronics Certification Board (ECB) web page.
You must have a
D0 UNIX
account to gain access to this page.
Go to the top of the page
Publications in IEEE Transactions on Nuclear Science
- B.Baldin, et al. "D0 Upgrade Muon Electronics Design,"
IEEE Trans. on Nuclear Science, Vol.42, No.4, pp 736-742, August 1995
Download
Postscript or
PDF file
- B.Baldin, et al. "D0 Muon Readout Electronics Design,"
IEEE Trans. on Nuclear Science, Vol.44, No.3, pp 363-369, June 1997
Download
Postscript or
PDF file
- B.Baldin, et al. "D0 Muon Proportional Drift Tube Electronics Test Results,"
IEEE Nuclear Science Symposium,
November 8-14 1998, Toronto, Ontario, Canada
Download
PDF file
Go to the top of the page
Muon Electronics Technical Design Report (D0 Note 3299):
(Adobe PDF file format, you can download
Adobe Acrobat Reader 4.0 from here)
Go to the top of the page
Last Modified on: December 08, 2003
This page is maintained by: Boris Baldin