-1: Inconsistent command line options when running from the command line. 1: Conditioner::getProbe: probe number out of range. 2: Conditioner::getProbe: Accessing position of probe that doesn't know its position yet. 3: Conditioner::setProbe: probe number out of range 4: Conditioner::setProbe: Setting probe that already had a position. 5: Calibrator::readRawData(): Cannot open input file with raw data 6: Calibrator::readRawData: Unexpected end of input file with raw data. 7: Cannot open output file dzdat[n].dat. Disk full? Non-existent directory? 31: Conditioner::updateProbe: probe number out of range 60: Calibrator::readRawData: Unexpected end of input file during reading of data. 999: Side::getNormal: Less than three points on this side, can't calculate normal. 1000+n: Calibrator::calibrate(): Cannot open input file result[n].out or dzdat[n].dat with data from/about conditioner [n] 1100: Trying to use conditioner data that doesn't exist. The calib. datafile was checked to exist, so this is an impossible error. Therefore abort. Time for some debugging. 1234: In HallProbe::applyStripRotation: Changed field strength! Bug in code. 1236: HallProbe::applyStripRotation: Unexpected angle of strip after rotation. 2001: Calibrator::ReadSurveyData: Unexpected end of file aligndat/surveydata_strips.dat 2002: Calibrator::ReadSurveyData: Unknown conditioner label 2003: Calibrator::ReadSurveyData: Unexpected end of file aligndat/surveydata_mountingblocks.dat 2004: Calibrator::processBlockPointLabel: Unknown conditioner label. 2006: Calibrator::readSurveyData: Cannot open survey-datafile aligndat/surveydata_strips.dat 2008: Calibrator::readRawData: Unexpected line found at end of measurement. Expecting "<----" or "STOP". 2009: Calibrator::readSurveyData: Cannot open survey file aligndat/surveydata_mountingblocks.dat 2010: Calibrator::applyStripAlignment: Cannot open file with strip alignments. 2011: Calibrator::applyStripAlignment: Unexpected EOF when reading header of file with strip alignments. 2012: Calibrator::applyStripAlignment: Unexpected EOF when reading data in file with strip alignments. 2013: Calibrator::applyStripAlignment: Not all heads on all conditioners know there survey data yet. 3010: MountingBlock::getProbePoints: Not all sides initialized (i.e. survey points set). 3011: MountingBlock::getProbePoints: Not all sides have 3 points or more. 3012: MountingBlock::set_orientation can't determine the inner side. The inner side is the side of the block facing towards the beam direction. 3013: MountingBlock:set_orientation can't determin the phi side. The phi side is the side facing in the direction of the phi-unit vector. 4001: Point::normalizeVec: After normalization, length is not 1. 4006: HallProbe::getNormal: Less than 3 points on this probe - unable to calculate plane for normal vector. 4007: "HallProbe::getZaxis: Less than 4 points on this probe - unable to calculate Z-axis. 4008: HallProbe::align: Internal B field not set 4009: HallProbe::getB_D0: Probe not aligned (i.e. aligment data not set for this probe yet) 4010: HallProbe::align: Alignment has changed B field strength - this means there is a bug!