The Run Plan can be found at http://www-d0.fnal.gov/runcoor/runplans/runplan.html
Note: The Run Plan has been split into the Current Daily plan and a separate page with the Standard Instructions. Please read both carefully and report any discrepancies.
The Run Plan Standard Instructions can be found at
http://www-d0.fnal.gov/runcoor/runplans/runplan_standard.html
This run plan covers:
The Captain's binder and instructions have been worked on by many people and has improved....but there is always room for improvement. While on shift with no beam or during quiet periods, Captains can assist in updating the documentation in the Captain binder. Please try and clean out obsolete instructions and update or create new instructions if they do not exist. If there are questions about some of the material, please send mail to Leslie.
Store 630 went in about noon with initial luminosity 2.6E30. Plan is to keep it (barring lightning and raccoons!) until Sunday, then shoot again.
Store 630 is to be used to collect sufficient global data for CFT light yield temperature dependence study. The solenoid and toroid are off for this. After collecting at least 100k events, the magnets should be turned on per the standing instructions (forward for both toroid and solenoid) for the next store. Contact the run coordinator if there are significant changes in the store plans.
L3 VRC3c tests are still ongoing and CAL crates might need to be taken out of the global run for these tests. If the tests are complete, the CAL crates should be included in the global runs.
Standing request from FPD for work on PW08 by Pierrick Hanlet during day or evening if there is an access.
Check the Standing Instructions for updated instructions on running the magnets.
The default trigger configuration file for collisions is still global_L1CalMuon-1.2.xml. This trigger file emphasizes muon triggers and some high Et jet and EM triggers. The rates should be kept in the range as indicated in the prescale file global_L1CalMuon-1.2-4e30_6Hz.prescales but can probably be tuned to achieve 10-15Hz. The prescale files is tuned expecting about 4E30 so will need to be tuned to achieve the desired rate. There is a lower luminosity trigger file also available (1E30).
DAQ Shifters should set prescales to maintain the desired data rates as specified in the trigger files. Captains should check to make sure the rates make sense and are within the desired ranges. Contact the Trigger Meisters or the Commissioning Coordinators if there are problems.