The Run Plan Standard Instructions can be found at http://www-d0.fnal.gov/runcoor/runplans/runplan_standard.html
The Current Daily Plan can be found at http://www-d0.fnal.gov/runcoor/runplans/runplan.html
The
default running condition for a store, unless otherwise specified and
approved by the Run Coordinator, is
to run with all available readout crates in the global run. Captains
are responsible for enforcing the run plans and resolving conflicts.
Work that influences or impacts the DAQ between stores must be
scheduled in advance and approved by the Commissioning Coordinator.
Requests for access should be written on the "white board" in the
control room and need to be approved by the Run Coordinator.
Sent mail to
d0accessrequests@fnal.gov.
Training needed is:
Film badges must be worn in the collision hall. Temporary badges are available in the control room.
DØ plans to move the Roman pots in to standard positions most stores not earlier than one hour after the beginning of the store. The MCR and CDF will be notified before pot motion and when it is concluded. The initial positions would be A1U=31.5 mm A1D=33.5 P1U=26 P1D=26.5 with A1=A2 and P1=P2 (previously determined as safe positions), with the beampipe axis roughly at 45mm. Pot insertion will be done cautiously while monitoring losses allowing time to react to an unanticipated change in beam orbit. DØ should be notified of any planned changes in beam position. The pots will remain at these positions for most/all of the store retracting the pots prior to the beam being aborted or machine studies.The MCR and CDF must be notified before any pot motion so they can watch for losses. CDF has asked to be notified about which pots are being moved so they can correlate the motion with their losses. FPD shifters will be present for all pot motion. The FPD pager number is (630) 266-2635 if there are any questions.Towards the end of the second store (t-4 hours) and some subsequent stores we plan to do studies to attempt to define closer operating positions (including initial dipole pot operating positions), since our acceptance is critically dependence on this. We would like to do these before any BD studies, which will require us to have the pots out and would render our default pot positions unreliable. Approval from BD run coordinator will be obtained prior to these studies. An acceptable new position for now is defined as one that does not increase the D0 losses by more than 10% and the pots will be retracted if CDF complains about high losses related to pot motion.
A few minutes before the store is terminated (D0 is supposed to receive a call from the MCR about planned terminations) Captain has to instruct DAQ expert to stop global running and ask detector experts to set their detector HV to "Standby". To avoid confusion, refer to the table below for which systems need to regulate their HV depending on beam conditions.
Luminosity counter phototubes are very sensitive to the presence of the solenoidal magnetic field. Whenever current in the solenoid is changed (turning solenoid ON, OFF or changing polarity) it is the responsibility of the Shift Captain to set the HV on the luminosity counters according to specific instructions outlined below by Gregor Geurkov. Note that the Luminosity HV stays ON at all times, even during beam studies, but the setting of the HV to lower or higher percentages depends on the solenoidal field being off or on.
| Beam conditions | |||||
|---|---|---|---|---|---|
| Detector | Shifter | Collisions | Injection | Beam studies | No Beam (Calibrations) |
| SMT | SMT shifter | 100% | OFF | OFF | 100% |
| CAL | CAL shifter | 100% at all times | |||
| ICD | CAL shifter | 100% at all times | |||
| MUON | MUON shifter | 100% | Standby | Standby | Standby |
| LUM | Captain | 50% at all times with solenoid off 70% at all times with solenoid on) | |||
Contact the Operations Technicians in DAB to ramp the magnets. The solenoid takes about 20 minutes to discharge and the toroid about 10 minutes. The shift captain should check with the operation technicians that these are interlocked after they are ramped down.
Plan for Magnet Operations
| Week of | 11/18 | 11/25 | 12/2 | 12/9 | 12/6 | 12/23 | 12/30 |
| Solenoid | R | R | F | F | R | F | F |
| Toroid | R | F | F | R | R | R | F |
The Day Shift Captain must attend the Beams Division 9am Meeting in Curia II in Wilson Hall (2nd floor, West side) on Mondays, Wednesdays and Fridays. The meeting normally lasts about 20 minutes. The Commissioning Coordinator normally attends and presents the report, but the Shift Captain should do so if the coordinators are not present.
The Captain should make sure that the Silicon Radiation Monitoring is running.
See the online instructions for details.
(http://www-d0.fnal.gov/~naeema/radmon/shift/procedure.htm)
At the end of a shift, Captains should follow Wyatt Merritt and Heidi Schellman's instructions on how to define a SAM dataset. The definition should define all the runs that are deemed good from the store that should be run through reco.
The default event display d0ve should be run at all times for colliding data
start_daq d0ve
Run Examines and Event displays at all times. In particular:
| Examine | Shifter | Node |
|---|---|---|
| Vertex Examine | Captain | d0ol04 |
| Event Display (d0ve) | DAQ shifter | d0ol10 |
| Calorimeter Examine | Calorimeter shifter | d0ol06 |
| Muon Examine | Muon shifter | d0ol09 |
| SMT Examine | SMT shifter | d0ol05 |
| CFT Examine | CFT shifter | d0ol08 |
COOR records the begin and end of runs along with the crate configurations.
DAQ shifters must still enter the relevant information in the taker
pop-up windows. For details, see the
message from Alan Stone.
DAQ Shifter should print the L1 and L3 trigger monitor
output page once per shift during colliding beam or after any major
configuration change.
Captains should summarize the runs taken with colliding beam
and indicate their quality:
At the begin of stores, the store number must be entered into COOR by the
DAQ shifter via
start end run# trigger #events toroid/solenoid crate list data quality (good/bad/unknown) Comments
(off,for,rev) (CAL,CFT,CPS,MUO,SMT)
These summaries should be put into the shift summary for distribution to
d0shifters and posted to
D0NEWS in the OPERATIONS folder.
Similarly, the end of store command is
At the beginning of a store, Captains should record all the information from
Channel 13 (the Beam's Status page) in the elog.
Contact Information
Office Pager Cell Home
Run Coordinator Dmitri Denisov x3851 (630) 218-4498 (630) 531-0413 (630) 879-6725
Commissioning Coordinator
Leslie Groer x5587 (630) 218-8421 (630) 399-0024 (630) 208-8151
DAQ On-Call Troubleshooter (630) 218-4801
Send comments/corrections to Leslie Groer
Last modified: Tue Oct 22 05:44:28 CDT 2002