DØ Current Access Request List

Last Update: July 27, 2001 - Leslie Groer

Muon Surveys - From Richard Smith, Al Ito, July 27, 2001

There are (only!) three muon survey jobs remaining on our job list: Each of these jobs requires 2 or more days, and all are supervised access, not controlled access.

Forward Proton Detector

Access required to the Collision Hall for two people for about 20 minutes. Call if between 7am-midnight.

Contact: FPD pager: (630) 266-2635


Forward Muon Detector - Basar Sabirov July 27, 2001

Repair short circuit in North C MDT octant 7. Contact person is Basar Sabirov (office x2889, home x3438, cell 630-399-2367).

Level 1 Muon System - Ken Johns, July 27, 2001

  1. Update MTCM FPGAs - 2 hrs
  2. Repair bad SFE-L1MU cable - 2 hrs
  3. Check rack cooling - 30 min
Ken Johns is not around July 18-20 but Jeff will be.

Calorimeter - from Ursula Bassler July 30, 2001

Two BLS Power supplies will not turn on due to undervolting.
  - Crate 10 bottom (ECN-SE)
  - Crate 2 bottom (CC-NW) Will need to pull the supplies and replace with spares. Need about 30-45 mins with 3 people per supply, during the day (prior to 2:30pm).
Short access needed (20 min) to reset Calorimeter Pulser LVPS in ECS-SE (06).

Contacts: Nirmalya Parua x6792, 218-8489 (pager) or Ursula Bassler x8740, 218-4777 (pager)


Contacts Leslie Groer or Michael Begel
Last modified: Tue Jul 31 20:33:43 CDT 2001