Date: Mon, 11 Feb 2002 17:11:10 -0600 From: Geoff Savage Subject: automatic pausing of runs The significant event system now has the ability to automatically pause runs when a severe condition is detected. The actual run pausing is handled by COOR and has not been turned on the configuration files. You will hear the speakers notify you that a run pause condition has been detected and the alarm will appear in the Alarm watcher row of the alarm display. If the alarm condition is a glitch (i.e. it goes bad then good so quickly it does not appear in the major column of the alarm display) it will appear in the good column of the alarm display. If the alarm condition persists you will hear a reminder every two minutes. There are two ways to eliminate the run pause alarm condition: 1. resolve the problem or 2. acknowledge the alarm in the alarm display. Remember that an acknowledged alarm will never again say anything so unacknowledge as soon as possible. During shifts the shifter and captain should monitor the accuracy of the system to see if conditions which arise need to pause a run. Please note any conditions that you feel should have paused a run but did not. This will allow the detector groups to configure their software appropriately. If any problems arise please email me. Geoff