Run Plan
  From:  DAY Mon May 3, 2004
  To:    DAY Mon May 10, 2004
Please send comments to the DØ Run Coordinator  
Last modified: Mon May 3 24:00:00 CDT 2004 by webermi  
Links:
D0 Operations
D0 at Work
Shift Captain
DAQ Shifters
Archives
Run Database
Rates for Current Store
Luminosity Reports
Run II Bests
daqAI
DZero ACNET
Photos

D0 Restricted:
Stores and Runs

MCR & CDF:
Accelerator Schedule
Beam Status (Ch 13)
MCR E-log
CDF E-log
AD Run Coordinator
Plots:
D0 Integrated Luminosity
D0 Efficiency (monthly)
D0 Efficiency (daily)
D0 Weekly Summary
D0 Monthly Summary
Control Room Procedures Index
BLS Power Supplies
Calorimeter for Non-CAL Shifters
CFT Operations
CFT Shifter On-Call
Changing Prescales
Controlled Accesses
Combined Test Stand Operations
Disable/Enable Muon Front-End
FPD Operations
FPD Procedures for Non-Experts
GM Instructions for Non-Experts
D0 High Voltage
L1CTT Inputs to L1 Muon
L1 Muon Trigger
Luminosity
Magnet Operations
Muon Shifter On-Call
Power Outage Recovery
Resetting Trips Due to Water Drip Detection
Resetting the NIKHEF Hall Probes
SCL Inits
SMT Voltage
STT Operations
TLD Badges
Training

Current Situation and Plans

  • Approved special runs:
    1. Special run for new trigger list.
    2. Special FPD run (timing scan). To be taken in case data quality is seriously compromised for a subsystem.

  • Run Plan is "stack and store". Collect quality data with the full detector in readout. Commissioning activities should occur between stores, unless approved by the run coordinator. Between stores, collect zero-bias data with as much of the detector as possible.
  • Prescale sets:
    The basic rule remains: "use the prescale set closest to the luminosity at the beginning of the run". See below for the list of available prescale sets. If the luminosity exceeds about 60E30, the L2 rates will be too high even with the 55E30 prescale set - in such a case, use the "Emergency" prescale set. Remember that first run in store should be ~2 hours as luminosity is dropping quickly at the begining of the store and optimization of prescales is needed.
  • Rescraping of the beam:
    MCR has repeatedly performed a rescraping of the beam in the middle of the store. In such a case, the regular end-of-store and begin-of-store procedures should be followed. In particular, the DAQ shifter should issue corresponding store_end and store_begin commands; for the luminosity accounting it is perfectly OK to fragment a single store into separate time periods.
  • The Shift Captain should follow the MCR e-log and call MCR as needed to keep up with the schedule of the AD. MCR may give D0 quiet time or a Controlled Access. Page the run coordinator for Controlled Access approval. See the whiteboard for Controlled Access requests.
  • Please read the D0 Logbook before your shift in order to be better prepared.

Magnet Polarities

from Tuesday May 4, 8:00:

   Solenoid = Reverse
   Toroid   = Forward

from Tuesday May 11, 8:00:

   Solenoid = Forward
   Toroid   = Forward

from Tuesday May 18, 8:00:

   Solenoid = Forward
   Toroid   = Reverse

See also Magnet Operations

Trigger Configuration

The default global trigger list is global_CMT-12.37.xml

Rules for Changing Prescales: choose the prescale set which has a name closest to the luminosity at the start of the run.

Available prescale sets for the above trigger are:

   02E30, 05E30, 08E30, 10E30, 13E30, 17E30, 20E30, 25E30,
   28E30, 35E30, 40E30, 45E30, 48E30, 55E30, Emergency, and scraping.
If help is needed with additional prescales, contact the Triggermeisters.

In this configuration, we see typical L1/L2/L3 accept rates of 600-1400/300-800/30-60 Hz, depending on the instantaneous luminosity and prescale set. If the rates are too high - L1>1500 or L2>850 or L3>65 Hz - or the global FEB exceeds 10%: contact the Triggermeister. A good effort should be made to keep the average global FEB rate below 6%.

Recorded Physics Run Limit:   4 hours    or   instantaneous rate in Taker < 25 Hz
In the case of bad luminosity lifetime (early in the store): start a new run with the appropriate prescale set after 2 hours

The DØ Shift Schedule (D0 Shift Calendar)

All Captain, DAQ and SMT shifts are 24/7.

Other shifters can be on-call:

  1. if there is no Store,
  2. if MCR states there is no shot setup expected for 4 or more hours,
  3. if the situation with the sub-detector is stable,
  4. if there are no sub-detector tasks to perform (checklist, calibration, special runs, monitoring), and
  5. if the Shift Captain is in agreement

Calorimeter, Muon and CFT Shifters do not need confirmation from their sub-detector coordinators. However, there are Special Instructions for Muon Shifters and Special Instructions for CFT/CPS/FPS Shifters which must be followed before leaving.

Shifters must report in with the Shift Captain to give a contact number before leaving.

Global Monitoring: Trigger & Physics Examines

Global Monitoring (GM) is being coordinated by Michiel Sanders and Elliot Cheu. The GM console, d0ol33, is reserved for the GM shifter during scheduled shifts when there is beam. Useful information, numbers and plots should be inserted into the electronic logbook under the GM tab.

The name of an institution will be listed next to the GM shifter when the Global Monitoring shift is being run remotely. There is a GM Web Communicator GUI to be used by the Shift Captain, remote GM Shifter, and other shifters as needed. The interface is very simple; shifters communicate via typed text. The gui should be open by default on the Captain console. If not, the gui can be launched with the following command sequence: setup d0online; start_daq gmwebcom.

The Shift Captain is running the vertex examine (currently on d0ol27). Michiel Sanders has documented the Vertex Examine Instructions (pdf and html). For reference, look at the VE plots entered in the logbook during previous shifts.

Periods Without a Shot Setup or Colliding Beams

During non-colliding beam, the  zero_bias_4L1L2L3MP-1.01.xml  trigger should be run with all available crates to exercise the DAQ as long as this does not conflict with commissioning or calibration efforts.

By default, 'Recording' should be ON as we would like to monitor the full data path from the detectors to tape at the Feynman Computing Center.

There are three trigger bits with prescales which have been tuned both to exercise the L1, L2 and L3 rates and to send an average of 1 Hz to tape, and a low rate L3 mark and pass trigger that writes to the monitor stream. The prescales should only be changed by or with approval of the triggermeisters.

If there is a request for cosmic ray data: the default cosmics trigger list is official/special/cosmics-3.00.xml. If the CTT is available, official/special/cosmics_trk-1.00.xml can also be used.