Magnet ramps must be approved by the Run Coordinator.
since Saturday October 22, 2005 :
Solenoid = Reverse
Toroid = Forward
We will change polarities twice each month, normally
when the magnets already need to
be ramped down. This still requires run coordinator approval. The next
change will be around 6 November and the polarity set will be:
Solenoid = Forward
Toroid = Reverse
See also
Magnet Operations
|
|
The default global trigger list is
global_CMT-14.70.xml
Rules for Selecting Prescales:
The prescale files have names with luminosity ranges.
Choose the prescale file for which the luminosity at the beginning of the run is within that range.
The luminosity may fall below the lower bound during the run.
Unless instructed otherwise by the trigger meisters, do not start a run with an initial luminosity not inside the correct prescale set.
Available prescale sets for the above trigger are:
00-10E30, 10-15E30, 15-20E30, 20-25E30, 25-30E30, 30-35E30, 35-40E30,
40-45E30, 45-50E30, 50-55E30, 55-60E30, 60-68E30, 68-76E30, 76-84E30,
84-92E30, 92-100E30, 100-108E30, 108-116E30, 116-124E30, 124-132E30,
132_and_up and scraping
If help is needed with additional prescales, contact the Triggermeister.
In this configuration, we should see typical L1/L2/L3 accept rates
of 300-1600/200-850/30-60 Hz,
depending on the instantaneous luminosity and prescale set.
If the rates are too high - L1>1700 or L2>900 or
L3>60 Hz (high luminosity) or 75 Hz (low luminosity) -
or the global FEB exceeds 10%: page the Triggermeister.
A good effort should be made to keep the global FEB rate below 7%.
Anytime the L3 disables are above 15%, change to the next higher prescale set.
Recorded Physics Run Limit:
- default 4 hours
- or 2 hours with a prescale set that is greater than 50E30.
- or change prescale if the instantaneous rate in the Taker is < 25 Hz
|
|
All Captain, DAQ and SMT shifts are 24/7.
Other shifters can be on-call:
- if there is no Store,
- if MCR states there is no shot setup expected for 4 or more hours,
- if the situation with the sub-detector is stable,
- if there are no sub-detector tasks to perform (checklist, calibration,
special runs, monitoring), and
- if the Shift Captain is in agreement
Muon and CFT Shifters do not need confirmation from their
sub-detector coordinators. However,
there are
Special Instructions for Muon Shifters and
Special Instructions for CFT/CPS/FPS Shifters which must be followed
before leaving. Calorimeter and SMT sub-detector coordinators would
need to be contacted before their shifter goes on call.
Shifters must report in with the Shift Captain to give a contact number before leaving.
|
|
Global Monitoring (GM) is now performed by the shift captain.
Global Monitoring is being coordinated by
Md Naimuddin and Elliot Cheu.
The GM console, d0ol33, is reserved for the GM tasks during the colliding beam operations.
Useful information, numbers and plots should be inserted into the
electronic logbook under the GM tab.
The vertex examine runs automatically (currently on d0ol77) and the Shift
Captain looks at the plots. Michiel Sanders has documented the Vertex Examine.
For reference, look at the VE plots entered in the logbook during
previous shifts.
|
|
During non-colliding beam, the
zero_bias_4L1L2L3MP-1.01.xml trigger
should be run with all available crates to exercise the DAQ.
By default, 'Recording' should be ON as we would like to monitor
the full data path from the detectors to tape at the Feynman Computing Center.
There are three trigger bits with prescales which have been tuned both to exercise
the L1, L2 and L3 rates and to send an average of 1 Hz to tape, and a low rate L3 mark
and pass trigger that writes to the monitor stream. The prescales should
only be changed by or with approval of the triggermeisters.
If there is a request for cosmic ray data: the default cosmics trigger list is
official/special/cosmics-3.10.xml.
|
|