Preliminary results for the CPS trigger
Last modified: Mon Aug 23 11:19:49 CDT 1999
L1 Algorithm: axial layer only
The strips are divided into
80 sectors
, just like the CFT phi sectors.
A threshold is required: E > 5 MeV (see plot 3)
L2 Algorithm: (u,v) layers
Link to Paul Grannis's page
CPS 's page
Dijets events
Occupancy in
AXIAL layer
for dijets events:
Dijet + 0 mbias: (results in percent)
Occupancy for 2 thresholds (plot 1-a)
Occupancy as f(Threshold) (plot 2-a)
Dijet + 2 mbias: (results in percent)
Occupancy for 2 thresholds (plot 1-b)
Occupancy as f(Threshold) (plot 2-b)
Single particle efficiency