The Level 2 Trigger Examine histograms The Level 2 Trigger Examine macros produce several histograms. Each histogram has a reference plot (the red solid line) from a past run, with data points (the black crosses) from the current run. The Global Monitor shifter is asked to watch for discrepancies between these plots. Global plots: The first group of histograms show quantities that have passed the Level 2 trigger. 1) number of L2 Global jets The number of jets in each event. 2) P_T of L2 Global jets The measured Pt of each jet (GeV). 3) eta of L2 Global jets Detector eta, from -2.4 to 2.4, of the jet seed tower. 4) phi of L2 Global jets Detector phi, from 0 to 2*pi, of the jet seed tower. 5) eta vs phi of L2 Global jets Scatter plot of plots #3 vs. #4. 6) number of L2 Global em objects The number of EM objects in each event. 7) P_T of L2 Global em objects The measured Pt of each EM object (GeV). 8) eta of L2 Global em objects Detector eta, from -2.4 to 2.4, of each EM object. 9) phi of L2 Global em objects Detector phi, from 0 to 2*pi, of each EM object. 10) eta vs phi of L2 Global em objects Scatter plot of plots #8 vs. #9. 11) isolation of L2 Global em objects 12) EM Fraction of Global L2 em objects EM fraction for each EM object, from 0 to 1. 13) number of L2 Global muons The number of muons in each event. 14) P_T threshold of L2 Global muons 15) eta of L2 Global muons Detector eta, from -2.4 to 2.4, of each muon. 16) phi of L2 Global muons Detector eta, from -2.4 to 2.4, of each muon. 17) eta vs phi of L2 Global muons Scatter plot of plots #15 vs. #16. 18) quality of L2 Global muons Muon quality. 1 = loose track 2 = medium track 3 = tight track 19) sign of L2 Global muons Sign of each muon, 0 = negative and 1 = positive. Preprocessor plots (or Worker plots): The remaining plots are from the Level 2 preprocessors (or L2 workers). They show the quantities that were passed to the L2 Global processor - the trigger inputs before cutting. 1) number of L2 cal EM objects The number of EM objects in each event. 2) E_T of L2 cal EM objects The measured Et of each EM object (GeV). 3) eta of L2 cal EM objects Detector eta, from -2.4 to 2.4, of each EM object. 4) phi of L2 cal EM objects Detector phi, from 0 to 2*pi, of each EM object. 5) eta vs phi of L2 cal EMs Scatter plot of plots #3 vs. #4. 6) EM Fraction of L2 cal EM objects EM fraction for each EM object, from 0 to 1. 7) isolation of L2 cal EM objects 8) number of L2 cal jets The number of jets in each event. 9) E_T of L2 cal jets The measured Et of each jet (GeV). 10) eta of L2 cal jets Detector eta, from -2.4 to 2.4, of the jet seed tower. 11) phi of L2 cal jets Detector phi, from 0 to 2*pi, of the jet seed tower. 12) eta vs phi of L2 cal jets Scatter plot of plots #10 vs. #11. 13) number of L2 preprocessor muons The number of muons in each event. 14) eta of L2 preprocessor muons Detector eta, from -2.4 to 2.4, of each muon. 15) phi of L2 preprocessor muons Detector eta, from -2.4 to 2.4, of each muon. 16) eta vs phi of L2 preprocessor muons Scatter plot of plots #14 vs. #15.